For the complete documentation index, see llms.txt. This page is also available as Markdown.

Reference and FAQ

This page consolidates limits, common error messages, and frequently asked questions for Guardrail on AI Platform. For step-by-step instructions, see Using Guardrails.


Limits

Item
Limit

Guardrails per account

Per system quota (exceeding it returns "Exceeded GUARDRAILS quota.").

Word filter

Up to 10,000 words; each word ≤ 100 characters and ≤ 3 words.

Prompt-based

Up to 10 rules; name ≤ 100 characters, unique.

Regex

Up to 10 patterns; pattern ≤ 255 characters, must be valid.

Score

0.0 – 1.0 for both PII and regex; defaults to 0.5.

Model / Guardrail

Each model attaches to only one Guardrail at a time.

System prompt

Not scanned by default; use the <vng-guard-content> tag to scan it.

Self-hosted / BYOK models

Guardrail attachment not yet supported.


Common error messages

Request returns 400

Symptom
Cause
Fix

Prompt has been rejected by AI Guard + reason naming a rule

The prompt-based filter flagged a violation

Review the outgoing content; for false positives, narrow the rule description or switch the action to Detect.

Request blocked due to detected keyword

Word filter hit a keyword with action Block

Remove the word, or switch the action to Detect/Mask if it blocks in error.

400 error when creating/editing on the Console

Field rule violation (malformed name, broken regex pattern, duplicate names…)

Read the error message — it names the offending field; cross-check the rules in Create a Guardrail.

Guardrail does not block content it should

Cause
Fix

The content is in a system prompt without a tag

Insert <vng-guard-content> before the part that needs scanning (see Scan the system prompt).

Misspelled tag

Copy the exact string <vng-guard-content> — a single wrong character makes it ineffective, with no error.

Prompt-based rule description too narrow

Add a clearer description / add rules for new violation patterns.

Model not attached to the Guardrail

Check the Protected models column; re-attach via Manage Models.

Operation rejected

Message
Cause
Fix

Guardrails is attached to one or more models. Please detach them first.

Deleting a Guardrail that still has attached models

Manage Models → deselect all → Save → delete again.

Model 'X' is already attached to guardrails 'Y'

The model belongs to another Guardrail

Detach the model from Guardrail 'Y' first.

Another guardrails attach/detach is in flight for this user. Please wait.

Another attach/detach operation is running

Wait a few seconds and retry.

Guardrails is <status>. Please wait for provisioning to complete and retry.

The Guardrail is not ACTIVE yet

Wait until the status is ACTIVE and retry.

Exceeded GUARDRAILS quota.

Guardrail quota exceeded

Delete unused Guardrails or contact support to raise the quota.


FAQ

Does Guardrail slow down requests?

Somewhat. Word filters are fast; the prompt-based filter calls an additional "judge" model and is slower. For clean content, this overhead is small compared to the main model's response generation time.

Do I have to change my client code?

No. Attach the Guardrail to a model and you are done — endpoint, headers, and body stay the same.

Why am I getting a 400 "Prompt has been rejected by AI Guard"?

The request content (or the system prompt portion after the <vng-guard-content> tag) was flagged by the prompt-based filter. The reason field tells you which rule caught it — see Common error messages.

Can Sensitive information "Block"?

No. This filter always rewrites content (mask/replace/delete) before sending — the goal is that data reaching the model is already safe.

What if my system prompt happens to contain the exact string <vng-guard-content>?

That is exactly how the tag works: everything from that position onward will be scanned. If that is not what you want, rephrase the prompt to avoid the exact tag string.

How many models can one Guardrail attach to?

As many as you like (among the MaaS models you have enabled), as long as each model is not already attached to another Guardrail.

Do I need to re-attach models after changing a Guardrail's configuration?

No. Configuration changes apply automatically to attached models (the Guardrail is in UPDATING status while applying).

Does Guardrail also apply to model responses?

Currently Guardrail checks input requests (the content you send). Model responses do not pass through Guardrail yet.


When to contact support

If the error persists or is not covered above, contact support with:

  • The Guardrail ID (gr-…) and affected model

  • The time it occurred and the region

  • The HTTP status and error content received

Last updated